Hello , Sign In
The heating oven Um is a Class I medical device.
Product Type | Universal Oven |
---|---|
Altitude of Installation | Max. 2,000 M Above Sea Level |
Ambient Temperature | +5 °C to +40 °C |
Chamber Volume | 108 L |
Material | Zinc-Plated Steel |
Voltage Rating | 115 V;230V |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Frequency Rating | 50/60 Hz |
Controlcockpit | Singledisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With High-Definition TFT-Colour Display |
Convection | Natural Convection |
Door Type | Fully Insulated |
Interior Dimensions | 560 x 480 x 400 mm |
Exterior Dimensions | 745 x 864 x 584 mm |
Dimensions | 745 x 864 x 584 mm |
Operating Temperature Range | 5 to 300 °C |
Display Type | Single;TFT Display |
Door | Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock) |
Weight | 74 kg |
Fresh Air | Admixture of Pre-Heated Fresh Air By Electronically Adjustable Air Flap |
Standards Met | CE Certified;DVE;cUL US Listed |
Power Rating | 1800 W;2800 W |
Relative Humidity | Maximum 80 (Non-Condensing) % |
Housing | Rear Zinc-Plated Steel |
Humidity RH | Max. 80 %, Non-Condensing |
Interior | Easy-To-Clean Interior,Made of Stainless Steel, Reinforced By Deep Drawn Ribbing With Integrated and Protected Large-Area Heating on Four Sides |
Maximum Loading of Internal | 20 kg |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Programming Software | AtmoCONTROL Software |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 175 Kg |
Maximum Loading Per Internal | 20 Kg |
Maximum Number of Internals | 5 |
Net Weight | Approx. 74 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software for Reading Out, Managing and Organising The Data Logger Via Ethernet Interface (temporary Trial Version Can Be Downloaded). USB Stick With Atmocontrol Software Available As Accessory (on Demand). |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | Up to 99.9 °C: 0.1 / From 100 °C: 0.5 |
Setting Temperature Range | +20 to +300 °C |
Temperature Sensor | 1 Pt100 Sensor Din Class a In 4-Wire-Circuit |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Vent | Vent Connection With Restrictor Flap |
Voltage Electrical Load | 230 V, 50/60 Hz ,2800 W~115 V, 50/60 Hz ,1800 W |
Volume | 108 L |
Working Temperature Range | At Least 5 (UN/UNplus/UNm/UNmplus) or 10 (UF/UFplus/UFm/UFmplus) Above Ambient Temperature to +300 °C |
Works Calibration Certificate | Calibration at +160°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Air Flap Position, Programme Time, Time Zones, Summertime/Wintertime |
Creating an account has many benefits: