Hello , Sign In
Sets eco standards for cultivation below room temperature: unmatched energy efficiency, best values for heat-up, cool-down and recovery times.
Altitude of Installation | Max. 2,000 M Above Sea Level |
---|---|
Product Type | Peltier-Cooled Incubator |
Ambient Temperature | 16 °C to 28 °C |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Controlcockpit | Singledisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With High-Definition TFT-Colour Display |
Convection | Forced Ventilation By Peltier Fan |
Timer Range | 1 min to 99 days |
Chamber Volume | 32 L |
Dimensions | 585 x 704 x 506 mm |
Interior Dimensions | 400 x 320 x 250 mm |
Door | Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)~Inner Glass Door |
Exterior Dimensions | 585 x 704 x 434 mm |
Voltage Rating | 115 V;230V |
Frequency Rating | 50/60 Hz |
Housing | Rear Zinc-Plated Steel |
Number of Shelves | 1;3 (Maximum) |
Humidity RH | Max. 70 %, Non-Condensing |
Weight | 40 kg |
Internals | 1 Stainless Steel Grid(S), Electropolished |
Standards Met | CE Certified;EAC |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 60 Kg |
Power Rating | 140 W |
Material | Zinc-Plated Steel |
Maximum Loading Per Internal | 20 Kg |
Relative Humidity | Maximum 70 (Non-Condensing) % |
Maximum Number of Internals | 3 |
Net Weight | Approx. 40 Kg |
Overvoltage Category | II |
Maximum Loading of Internal | 20 kg |
Peltier | Energy-Saving Peltier Heating-/Cooling System Integrated In The Rear (heat Pump Principle) |
Pollution Degree | 2 |
Software Requirement | AtmoCONTROL |
Programming | Atmocontrol Software for Reading Out, Managing and Organising The Data Logger Via Ethernet Interface (temporary Trial Version Can Be Downloaded). USB Stick With Atmocontrol Software Available As Accessory (on Demand). |
Operating Temperature Range | 0 to 70 (without Light) °C |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | 0.1 °C |
Setting Temperature Range | 0 to +70 °C |
Temperature Sensor | 1 Pt100 Sensor Din Class a In 4-Wire-Circuit |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Voltage Electrical Load | 230 V, 50/60 Hz ,140 W~115 V, 50/60 Hz ,140 W |
Volume | 32 L |
Working Temperature Range | Without Light: From 0 (at Least 20 Below Ambient Temperature) to +70°C |
Works Calibration Certificate | For +10°C and +37°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Programme Time, Time Zones, Summertime/Wintertime |