Hello , Sign In
Sets eco standards for cultivation below room temperature: unmatched energy efficiency, best values for heat-up, cool-down and recovery times.
Altitude of Installation | Max. 2,000 M Above Sea Level |
---|---|
Product Type | Peltier-Cooled Incubator |
Ambient Temperature | 16 °C to 28 °C |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Controlcockpit | Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays. |
Convection | Forced Ventilation By Peltier Fan |
Timer Range | 1 min to 99 days |
Chamber Volume | 1060 L |
Dimensions | 1224 x 1720 x 1005 mm |
Interior Dimensions | 1040 x 1200 x 850 mm |
Door | Inner Glass Doors~Fully Insulated Stainless Steel Doors With 2-Point Locking (compression Door Lock) |
Exterior Dimensions | 1224 x 1720 x 1005 mm |
Voltage Rating | 115 V;230V |
Frequency Rating | 50/60 Hz |
Housing | Rear Zinc-Plated Steel |
Number of Shelves | 2 (Standard);14 (Maximum) |
Humidity RH | Max. 70 %, Non-Condensing |
Installation | On Lockable Castors |
Weight | 248 kg |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Standards Met | CE Certified;EAC |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 200 Kg |
Power Rating | 1300 W |
Material | Zinc-Plated Steel |
Maximum Loading Per Internal | 20 Kg |
Relative Humidity | Maximum 70 (Non-Condensing) % |
Maximum Number of Internals | 14 |
Net Weight | Approx. 248 Kg |
Overvoltage Category | II |
Maximum Loading of Internal | 20 kg |
Peltier | Energy-Saving Peltier Heating-/Cooling System Integrated In The Rear (heat Pump Principle) |
Pollution Degree | 2 |
Software Requirement | AtmoCONTROL |
Programming | Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port |
Operating Temperature Range | 0 to 70 (without Light) °C |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | 0.1 °C |
Setting Temperature Range | 0 to +70 °C |
Temperature Sensor | 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Voltage Electrical Load | 230 V, 50/60 Hz ,1300 W~115 V, 50/60 Hz ,1300 W |
Volume | 1060 L |
Working Temperature Range | Without Light: From 0 (at Least 20 Below Ambient Temperature) to +70°C |
Works Calibration Certificate | For +10 °C, +25 °C and +40 °C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Programme Time, Time Zones, Summertime/Wintertime |