Hello , Sign In
Active humidity control creates a controlled environment for accelerated life tests and 85/85 tests.
Product Type | Humidity Chamber |
---|---|
Alarm | Visual and Acoustic |
Altitude of Installation | Max. 2,000 M Above Sea Level |
Chamber Volume | 107 L |
Humidity Range | 70 % (Non-Condensing) |
Autodiagnostic System | Integral Fault Diagnostics for Temperature and Humidity Control |
Calibration | Three Freely Selectable Values Each, Temperature and Humidity |
Controlcockpit | Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays. |
Sensor Type | PT100 Sensor |
Interior Dimensions | 560 x 480 x 400 mm |
Dimensions | 719 x 850 x 591 mm |
Exterior Dimensions | 719 x 850 x 591 mm |
Voltage Rating | 230 V;115V |
Door | Additional Heated Inner Glass Door~Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock) |
Volume | 107 L |
Frequency Rating | 50/60 Hz |
Entry Port | Entry Port (silicone), 40 mm Clear Diameter, for Introducing Connections, Moisture Tight, Can Be Closed By Silicone Stopper, at The Back, Centre Left |
Standards Met | CE Certified;DVE GS;cMET US Listed;EAC |
Ambient Temperature | 10 °C to 30 °C |
Humidity RH | Max. 70 %, Non-Condensing |
Power Rating | 1720 W |
Interface | Ethernet LAN, USB |
Weight | 75 kg |
Maximum Loading of Internal | 15 kg |
Internals | 2 Perforated Stainless Steel Shelf/Shelves |
Material | stainless steel |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 90 Kg |
Maximum Loading Per Internal | 15 Kg |
Maximum Number of Internals | 6 |
Net Weight | Approx. 75 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Humidity | 0.5 % Rh |
Setting Accuracy Temperature | 0.1 °C |
Setting Range Active Humidity Control | 20 to 95 % Rh and Rh-Off |
Setting Temperature Range | +18 to +90 °C |
Standard Accessories | Water Tank Including Connection Hose |
Temperature Sensor | 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Voltage Electrical Load | 230 V, 50/60 Hz ,1720 W~115 V, 50/60 Hz ,1720 W |
Working Temperature Range | +7 Above Ambient Temperature Up to +90 °C |
Works Calibration Certificate | Works Calibration Certificate (measuring Point Chamber Centre) at 60 °C With 75 % Rh |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Relative Humidity, Programme Time, Time Zones, Summertime/Wintertime |