The indispensable safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all time
Accessory Type | Steriliser |
---|---|
Altitude of Installation | Max. 2,000 M Above Sea Level |
Ambient Temperature | +5 °C to +40 °C |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Controlcockpit | Singledisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With High-Definition TFT-Colour Display |
Operating Temperature Range | 5 to 250 °C |
Power Supply | 400 V;3 Phase;50 Hz;5800 W |
Weight | 161 kg |
Warranty | 3 yr |
Dimensions | 1224 x 1247 x 784 mm |
Material | Zinc-Plated Steel |
Relative Humidity | Maximum 80 (Non-Condensing) % |
Door | Fully Insulated Stainless Steel Doors With 2-Point Locking (compression Door Lock), Lockable |
Fresh Air | Admixture of Pre-Heated Fresh Air By Electronically Adjustable Air Flap |
Maximum Loading of Internal | 30 kg |
Housing | Rear Zinc-Plated Steel |
Humidity RH | Max. 80 %, Non-Condensing |
Interior | Easy-To-Clean Interior,Made of Stainless Steel, Reinforced By Deep Drawn Ribbing With Integrated and Protected Large-Area Heating on Four Sides |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 300 Kg |
Maximum Loading Per Internal | 30 Kg |
Maximum Number of Internals | 8 |
Net Weight | Approx. 161 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software for Reading Out, Managing and Organising The Data Logger Via Ethernet Interface (temporary Trial Version Can Be Downloaded). USB Stick With Atmocontrol Software Available As Accessory (on Demand). |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | Up to 99.9 °C: 0.1 / From 100 °C: 0.5 |
Setting Temperature Range | +20 to +250 °C |
Temperature Sensor | 1 Pt100 Sensor Din Class a In 4-Wire-Circuit |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Vent | Vent Connection With Restrictor Flap |
Voltage Electrical Load | 400 V and 3x 230 V W/O Neutral, 50/60 Hz Approx. 5800 W |
Volume | 449 L |
Working Temperature Range | At Least 5 Above Ambient Temperature to +250 °C |
Works Calibration Certificate | Calibration at +160°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Air Flap Position, Programme Time, Time Zones, Summertime/Wintertime |
Installation | On Lockable Castors |
Convection | Natural Convection |