Toggle Nav
Toggle Nav
My Account

Hello , Sign In

MEMMERT Hot Air Steriliser SN160plus, 161 L, 20-250°C

CAD $ 7,680.00
In stock
Overview
SKU
SN160plus

MEMMERT Hot Air Steriliser SN160plus, 161 L, 20-250°C

Overview
MEMMERT Hot Air Steriliser SN160plus, 161 L, 20-250°C
Overview

The indispensable safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all time

More Information
Alarm Visual and Acoustic
Accessory Type Steriliser
Altitude of Installation Max. 2,000 M Above Sea Level
Ambient Temperature +5 °C to +40 °C
Autodiagnostic System For Fault Analysis
Calibration Three Freely Selectable Temperature Values
Controlcockpit Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays.
Operating Temperature Range 5 to 250 °C
Power Supply 230 V;50/60 Hz;3200 W
Weight 96 kg
Warranty 3 yr
Dimensions 745 x 1104 x 584 mm
Material Zinc-Plated Steel
Relative Humidity Maximum 80 (Non-Condensing) %
Door Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)
Fresh Air Admixture of Pre-Heated Fresh Air By Electronically Adjustable Air Flap
Maximum Loading of Internal 20 kg
Function Heatbalance Adapting The Distribution of The Heating Performance of The Upper and Lower Heating Circuit From -50 % to +50 %
Housing Rear Zinc-Plated Steel
Humidity RH Max. 80 %, Non-Condensing
Interior Easy-To-Clean Interior,Made of Stainless Steel, Reinforced By Deep Drawn Ribbing With Integrated and Protected Large-Area Heating on Four Sides
Internals 2 Stainless Steel Grid(S), Electropolished
Language Setting German, English, Spanish, French, Polish, Czech, Hungarian
Maximum Loading of Chamber 210 Kg
Maximum Loading Per Internal 20 Kg
Maximum Number of Internals 8
Net Weight Approx. 96 Kg
Overvoltage Category II
Pollution Degree 2
Programming Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port
Set Up The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm.
Setting Accuracy Temperature Up to 99.9 °C: 0.1 / From 100 °C: 0.5
Setting Temperature Range +20 to +250 °C
Temperature Sensor 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error
Timer Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days
Vent Vent Connection With Restrictor Flap
Voltage Electrical Load 230 V, 50/60 Hz ,3200 W~115 V, 50/60 Hz ,1800 W
Volume 161 L
Working Temperature Range At Least 5 Above Ambient Temperature to +250 °C
Works Calibration Certificate Calibration at +160°C
Adjustable Parameters Temperature (Celsius or Fahrenheit), Air Flap Position, Programme Time, Time Zones, Summertime/Wintertime
Convection Natural Convection
No Records Found