Hello , Sign In
The indispensable safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all time
Alarm | Visual and Acoustic |
---|---|
Accessory Type | Steriliser |
Altitude of Installation | Max. 2,000 M Above Sea Level |
Ambient Temperature | +5 °C to +40 °C |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Controlcockpit | Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays. |
Operating Temperature Range | 10 to 250 °C |
Power Supply | 230 V;50/60 Hz;2800 W |
Weight | 74 kg |
Warranty | 3 yr |
Dimensions | 745 x 864 x 584 mm |
Material | Zinc-Plated Steel |
Relative Humidity | Maximum 80 (Non-Condensing) % |
Door | Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock) |
Fan | Forced Air Circulation By Quite Air Turbine, Adjustable In 10 % Steps for Each Segment Individually |
Fresh Air | Admixture of Pre-Heated Fresh Air By Electronically Adjustable Air Flap |
Maximum Loading of Internal | 20 kg |
Function Heatbalance | Adapting The Distribution of The Heating Performance of The Upper and Lower Heating Circuit From -50 % to +50 % |
Housing | Rear Zinc-Plated Steel |
Humidity RH | Max. 80 %, Non-Condensing |
Interior | Easy-To-Clean Interior,Made of Stainless Steel, Reinforced By Deep Drawn Ribbing With Integrated and Protected Large-Area Heating on Four Sides |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Chamber | 175 Kg |
Maximum Loading Per Internal | 20 Kg |
Maximum Number of Internals | 5 |
Net Weight | Approx. 74 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | Up to 99.9 °C: 0.1 / From 100 °C: 0.5 |
Setting Temperature Range | +20 to +250 °C |
Temperature Sensor | 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Vent | Vent Connection With Restrictor Flap |
Voltage Electrical Load | 230 V, 50/60 Hz ,2800 W~115 V, 50/60 Hz ,1800 W |
Volume | 108 L |
Working Temperature Range | At Least 10 Above Ambient Temperature to +250°C |
Works Calibration Certificate | Calibration at +160°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Fan Speed, Air Flap Position, Programme Time, Time Zones, Summertime/Wintertime |
Creating an account has many benefits: