Toggle Nav
Toggle Nav
My Account

Hello , Sign In

Please sign in to access your order updates

MEMMERT Constant Climate Chamber HPP260eco, 256 L, 0-70°C, 10-90% rh

$22,160.00
In stock
Overview
SKU
HPP260eco

MEMMERT Constant Climate Chamber HPP260eco, 256 L, 0-70°C, 10-90% rh

Overview
MEMMERT Constant Climate Chamber HPP260eco, 256 L, 0-70°C, 10-90% rh
Overview

Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests for cosmetics and foods as well as environmental testing and material testing

More Information
Alarm Visual and Acoustic
Product Type Constant Climate Chamber
Altitude of Installation Max. 2,000 M Above Sea Level
Chamber Volume 256 L
Ambient Temperature 16 °C to 28 °C
Humidity Range 70 % (Non-Condensing)
Autodiagnostic System Integral Fault Diagnostics for Temperature and Humidity Control
Calibration Three Freely Selectable Values Each, Temperature and Humidity
Sensor Type PT100 Sensor
Interior Dimensions 640 x 800 x 500 mm
Dimensions 824 x 1183 x 655 mm
Exterior Dimensions 824 x 1183 x 655 mm
Weight 101  kg
Voltage Rating 230 V;115V
Frequency Rating 50/60 Hz
Door Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)~Inner Glass Door
Standards Met CE Certified;EAC
Power Rating 700  W
Maximum Loading of Internal 20 kg
Housing Rear Zinc-Plated Steel
Material Zinc-Plated Steel
Humidification Humidification By Hot Steam Generator
Humidity RH Max. 70 %, Non-Condensing
Internals 2 Stainless Steel Grid(S), Electropolished
Maximum Loading Per Internal 20 Kg
Maximum Number of Internals 9
Net Weight Approx. 101 Kg
Pollution Degree 2
Programming Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port
Set Up The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm.
Setting Accuracy Temperature 0.1 °C
Temperature Sensor 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error
Timer Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days
Volume 256 L
Controlcockpit Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays.
Dehumidification Dehumidification By Cold Trap Using The Peltier Technology
Humidity Humidity Supply With Distilled Water From External Tank By Self-Priming Pump
Interface Ethernet LAN, USB
Language Setting German, English, Spanish, French, Polish, Czech, Hungarian
Maximum Loading of Chamber 200 Kg
Overvoltage Category II
Peltier Energy-Saving Peltier Heating-/Cooling System Integrated In The Rear (heat Pump Principle)
Setting Accuracy Humidity 0.5 % Rh
Setting Range Humidity 10 - 90 % Rh
Setting Temperature Range Without Light, With Humidity: +5 to +70 °C~with Light, With Humidity: +5 to +70 °C~with Light, Without Humidity: 0 to +70 °C~without Light, Without Humidity: 0 to +70 °C
Standard Accessories Water Tank Including Connection Hose
Standard Works Calibration Certificate +25 °C / 60 % Rh, +40 °C / 75 % Rh
Voltage Electrical Load 230 V, 50/60 Hz ,700 W~115 V, 50/60 Hz ,700 W
Working Temperature Range With Light, Without or With Humidity: 15 to +40 °C~without Light, With Humidity: +5 (at Least 20 Below Ambient Temperature) to +70 °C~without Light, Without Humidity: 0 (at Least 20 Below Ambient Temperature) to +70 °C
Adjustable Parameters Temperature (Celsius or Fahrenheit), Relative Humidity, Programme Time, Time Zones, Summertime/Wintertime
No Records Found