Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage.
Air Jacket | Air Jacket Heating System for Gentle All-Around Heating |
---|---|
Product Type | Compressor-Cooled Incubator |
Alarm | Visual and Acoustic |
Altitude of Installation | Max. 2,000 M Above Sea Level |
Ambient Temperature | 15 °C to 28 °C (up to 34 °C With Limited Temperature Range) |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Timer Range | 1 min to 99 days |
Controlcockpit | Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays. |
Chamber Volume | 449 L |
Cooling | Energy-Saving Use of Cfc-Free Cooling/Heating System (refrigerant R134a) |
Interior Dimensions | 1040 x 720 x 600 mm |
Exterior Dimensions | 1224 x 1467 x 784 mm |
Defrosting | Highly Efficient Automatic Defrosting System |
Voltage Rating | 115 V;230V |
Dimensions | 1224 x 1467 x 784 mm |
Frequency Rating | 50 Hz |
Number of Shelves | 2 (Standard);8 (Maximum) |
Door | Inner Glass Doors~Fully Insulated Stainless Steel Doors With 2-Point Locking (compression Door Lock) |
Weight | 217 kg |
Standards Met | CE Certified;EAC |
Heating Concept | No Drying-Up of The Load Caused By The Cooling Device Due to Separation of Thermal Jacket From Interior |
Housing | Rear Zinc-Plated Steel |
Power Rating | 1200 W |
Material | Zinc-Plated Steel |
Humidity RH | Max. 70 %, Non-Condensing |
Relative Humidity | Maximum 70 (Non-Condensing) % |
Installation | On Lockable Castors |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Internal | 30 kg |
Maximum Loading of Chamber | 200 Kg |
Maximum Loading Per Internal | 30 Kg |
Software Requirement | AtmoCONTROL |
Maximum Number of Internals | 8 |
Operating Temperature Range | -12 to 60 °C |
Net Weight | Approx. 217 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | 0.1 °C |
Setting Temperature Range | -12 to +60 °C |
Temperature Sensor | 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Voltage Electrical Load | 230 V, 50/60 Hz ,1200 W~115 V, 50/60 Hz ,1200 W |
Volume | 449 L |
Working Temperature Range | From -12°C Up to +60°C (Optimum Performance of Cooling Aggregate at An Ambient Temperature of +16°C Up to +34°C. Not Suitable for Long-Term Storing at Sub-Zero Temperatures. During Permanent Operation, The Glass Door May Ice Over.) |
Works Calibration Certificate | For +10°C and +37°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Fan Speed, Programme Time, Time Zones, Summertime/Wintertime |