Hello , Sign In
Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage.
Air Jacket | Air Jacket Heating System for Gentle All-Around Heating |
---|---|
Product Type | Compressor-Cooled Incubator |
Alarm | Visual and Acoustic |
Altitude of Installation | Max. 2,000 M Above Sea Level |
Ambient Temperature | 15 °C to 28 °C (up to 34 °C With Limited Temperature Range) |
Autodiagnostic System | For Fault Analysis |
Calibration | Three Freely Selectable Temperature Values |
Timer Range | 1 min to 99 days |
Controlcockpit | Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays. |
Chamber Volume | 256 L |
Cooling | Cooling Compressor With Climate-Friendly Refrigerant CO2 (R744), Gwp1 |
Interior Dimensions | 640 x 800 x 500 mm |
Exterior Dimensions | 824 x 1552 x 684 mm |
Defrosting | Highly Efficient Automatic Defrosting System |
Voltage Rating | 230 V |
Dimensions | 824 x 1552 x 684 mm |
Frequency Rating | 50 Hz |
Number of Shelves | 2 (Standard);9 (Maximum) |
Door | Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)~Inner Glass Door |
Weight | 162 kg |
Standards Met | CE Certified;EAC |
Heating Concept | No Drying-Up of The Load Caused By The Cooling Device Due to Separation of Thermal Jacket From Interior |
Housing | Rear Zinc-Plated Steel |
Power Rating | 1200 W |
Material | Zinc-Plated Steel |
Humidity RH | Max. 70 %, Non-Condensing |
Relative Humidity | Maximum 70 (Non-Condensing) % |
Installation | On Lockable Castors |
Internals | 2 Stainless Steel Grid(S), Electropolished |
Language Setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Maximum Loading of Internal | 20 kg |
Maximum Loading of Chamber | 200 Kg |
Maximum Loading Per Internal | 20 Kg |
Software Requirement | AtmoCONTROL |
Maximum Number of Internals | 9 |
Operating Temperature Range | -12 to 60 °C |
Net Weight | Approx. 162 Kg |
Overvoltage Category | II |
Pollution Degree | 2 |
Programming | Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port |
Set Up | The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm. |
Setting Accuracy Temperature | 0.1 °C |
Setting Temperature Range | -12 to +60 °C |
Temperature Sensor | 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error |
Timer | Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days |
Voltage Electrical Load | 230 V, 50 Hz ,1200 W |
Volume | 256 L |
Working Temperature Range | From -12°C Up to +60°C (Optimum Performance of Cooling Aggregate at An Ambient Temperature of +16°C Up to +34°C. Not Suitable for Long-Term Storing at Sub-Zero Temperatures. During Permanent Operation, The Glass Door May Ice Over.) |
Works Calibration Certificate | For +10°C and +37°C |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), Fan Speed, Programme Time, Time Zones, Summertime/Wintertime |
Creating an account has many benefits: