Toggle Nav
Toggle Nav
My Account

Hello , Sign In

Please sign in to access your order updates

MEMMERT Compressor-cooled incubator ICP260eco, 256 L, -12-60°C

$18,506.00
In stock
Overview
SKU
ICP260eco

MEMMERT Compressor-cooled incubator ICP260eco, 256 L, -12-60°C

Overview
MEMMERT Compressor-cooled incubator ICP260eco, 256 L, -12-60°C
Overview

Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage.

More Information
Air Jacket Air Jacket Heating System for Gentle All-Around Heating
Product Type Compressor-Cooled Incubator
Alarm Visual and Acoustic
Altitude of Installation Max. 2,000 M Above Sea Level
Ambient Temperature 15 °C to 28 °C (up to 34 °C With Limited Temperature Range)
Autodiagnostic System For Fault Analysis
Calibration Three Freely Selectable Temperature Values
Timer Range 1 min to 99 days
Controlcockpit Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays.
Chamber Volume 256 L
Cooling Cooling Compressor With Climate-Friendly Refrigerant CO2 (R744), Gwp1
Interior Dimensions 640 x 800 x 500  mm
Exterior Dimensions 824 x 1552 x 684 mm
Defrosting Highly Efficient Automatic Defrosting System
Voltage Rating 230 V
Dimensions 824 x 1552 x 684 mm
Frequency Rating 50 Hz
Number of Shelves 2 (Standard);9 (Maximum)
Door Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)~Inner Glass Door
Weight 162 kg
Standards Met CE Certified;EAC
Heating Concept No Drying-Up of The Load Caused By The Cooling Device Due to Separation of Thermal Jacket From Interior
Housing Rear Zinc-Plated Steel
Power Rating 1200 W
Material Zinc-Plated Steel
Humidity RH Max. 70 %, Non-Condensing
Relative Humidity Maximum 70 (Non-Condensing) %
Installation On Lockable Castors
Internals 2 Stainless Steel Grid(S), Electropolished
Language Setting German, English, Spanish, French, Polish, Czech, Hungarian
Maximum Loading of Internal 20 kg
Maximum Loading of Chamber 200 Kg
Maximum Loading Per Internal 20 Kg
Software Requirement AtmoCONTROL
Maximum Number of Internals 9
Operating Temperature Range -12 to 60 °C
Net Weight Approx. 162 Kg
Overvoltage Category II
Pollution Degree 2
Programming Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port
Set Up The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm.
Setting Accuracy Temperature 0.1 °C
Setting Temperature Range -12 to +60 °C
Temperature Sensor 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error
Timer Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days
Voltage Electrical Load 230 V, 50 Hz ,1200 W
Volume 256 L
Working Temperature Range From -12°C Up to +60°C (Optimum Performance of Cooling Aggregate at An Ambient Temperature of +16°C Up to +34°C. Not Suitable for Long-Term Storing at Sub-Zero Temperatures. During Permanent Operation, The Glass Door May Ice Over.)
Works Calibration Certificate For +10°C and +37°C
Adjustable Parameters Temperature (Celsius or Fahrenheit), Fan Speed, Programme Time, Time Zones, Summertime/Wintertime
No Records Found