Toggle Nav
Toggle Nav
My Account

Hello , Sign In

Please sign in to access your order updates

MEMMERT CO2-Incubator ICO50med, 56 L, 18-50°C, CO2 Control 0-20%

$9,608.00
In stock
Overview
SKU
ICO50med

MEMMERT CO2-Incubator ICO50med, 56 L, 18-50°C, CO2 Control 0-20%

Overview
MEMMERT CO2-Incubator ICO50med, 56 L, 18-50°C, CO2 Control 0-20%
Overview

Safety at all times: High-end functions for the protection of cell cultures, bacteria cultures or tissue cultures.

More Information
Adjustable Parameters Temperature (Celsius or Fahrenheit), CO2, Programme Time, Time Zones, Summertime/Wintertime
Product Type CO2 Incubator
Adjustment Range CO2 0 to 20 % CO2
Adjustment Range O2 1 to 20 % O2
Alarm Visual and Acoustic
Altitude of Installation Max. 2,000 M Above Sea Level
Ambient Temperature 10 °C to 35 °C
Autodiagnostic System Integral Fault Diagnostics for Temperature and CO2
Chamber Volume 56 L
CO2 Control Digital Electronic CO2 Control With Dual Beam Ndir System, With Auto-Diagnostic System and Acoustic Fault Indication, Barometric Pressure Compensation
Controlcockpit Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays.
Interior Dimensions 400 x 425 x 330 mm
Exterior Dimensions 559 x 795 x 521 mm
Volume 56 L
Voltage Rating 115 V;230V
Dimensions 559 x 795 x 521 mm
Frequency Rating 50/60 Hz
Number of Shelves 1
Door Fully Insulated Stainless Steel Door With 2-Point Locking (compression Door Lock)~Inner Glass Door With Opening (8 mm Ø) to Take Gas Sample
Relative Humidity Maximum 70 (Non-Condensing) %
Standards Met CE Certified;cUL US Listed;DVE
Housing Rear Zinc-Plated Steel
Humidity Control Humidity Limitation Thanks to a Peltier Element; When Water Dish Is Full and Inserted, The Peltier Element Limits The Value of Relative Humidity In The Interior to 93 % Rh +/- 2.5 %
Power Rating 1100 W
Material Zinc-Plated Steel
Humidity RH Max. 70 %, Non-Condensing
Interface Ethernet LAN, USB
Interior Material 1.4301 (ASTM 304), Corrosion Resistant
Language Setting German, English, Spanish, French, Polish, Czech, Hungarian
Maximum Loading of Internal 15 kg
Maximum Loading of Chamber 75 Kg
Maximum Loading Per Internal 15 Kg
Software Requirement AtmoCONTROL
Weight 55 kg
Operating Temperature Range 18 to 50 °C
Maximum Number of Internals 5
Net Weight Approx. 55 Kg
Overvoltage Category II
Pollution Degree 2
Programming Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port
Set Up The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm.
Setting Accuracy CO2 0,1%
Setting Accuracy O2 0.1 % O2
Setting Accuracy Humidity 0.5 % Rh
Setting Accuracy Temperature 0.1 °C
Setting Range Active Humidity Control (with Option K7) 40 to 97 % Rh and Rh-Off
Setting Temperature Range +18 to +50 °C
Standard Accessories Membrane Filter (in Order to Remove Impurities and Pollutants, All Incoming Gases Pass Through a Membrane Filter Before They Reach The Chamber)
Standard Equipment CO2 Connection Set: Hose With Coupling and Clamp
Temperature Fluctuations With Time At 37 °C +/- 0.1 K
Temperature Sensor 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error
Temperature Variation In Chamber At + 37 °C +/- 0.3 K
Variation In Time CO2 +/- 0.2 % CO2
Voltage Electrical Load 230 V, 50/60 Hz ,1100 W~115 V, 50/60 Hz ,1100 W
Working Temperature Range 5 °C Above Ambient Temperature Up to +50 °C Standard Sterilisation Programme: 60 Minutes at 180°C (without Removing The Sensors)
Works Calibation Certificate Works Calibration Certificate at +37 °C, 5 % CO2 and 90 % Rh