Toggle Nav
Toggle Nav
My Account

Hello , Sign In

Please sign in to access your order updates

MEMMERT Climate Chamber ICH260L, with light, 256 L, 10-60°C with humidity 10-80% rh

$30,072.00
In stock
Overview
SKU
ICH260L

MEMMERT Climate Chamber ICH260L, with light, 256 L, 10-60°C with humidity 10-80% rh

Overview
MEMMERT Climate Chamber ICH260L, with light, 256 L, 10-60°C with humidity 10-80% rh
Overview

Unparalleled homogeneity of temperature and humidity. For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP – GCCP.

More Information
Alarm Visual and Acoustic
Product Type Climate Chamber
Altitude of Installation Max. 2,000 M Above Sea Level
Chamber Volume 256 L
Ambient Temperature 15 °C to 28 °C (up to 34 °C With Limited Temperature Range)
Humidity Range 70 % (Non-Condensing)
Autodiagnostic System Integral Fault Diagnostics for Temperature and Humidity Control
Calibration Three Freely Selectable Values Each, Temperature/Humidity/CO2
Cooling Cooling Compressor With Climate-Friendly Refrigerant CO2 (R744), Gwp1
Sensor Type PT100 Sensor
Interior Dimensions 640 x 800 x 500 mm
Dimensions 824 x 1552 x 685 mm
Exterior Dimensions 824 x 1552 x 685 mm
Weight 160  kg
Voltage Rating 230 V;115V
Frequency Rating 50/60 Hz
Door Inner Glass Doors~Fully Insulated Stainless Steel Doors With 2-Point Locking (compression Door Lock)
Standards Met CE Certified;EAC
Entry Port Entry Port (silicone), 40 mm Clear Diameter, Moisture Tight, Can Be Closed By a Silicone Stopper, Standard Position at The Back
Power Rating 1450  W
Fan Forced Air Circulation In Working Chamber Adjustable From 10 to 100 % In 10 % Steps
Maximum Loading of Internal 20 kg
Housing Rear Zinc-Plated Steel
Material Zinc-Plated Steel
Humidification Humidification By Hot Steam Generator
Humidity RH Max. 70 %, Non-Condensing
Installation On Lockable Castors
Internals 2 Stainless Steel Grid(S), Electropolished
Maximum Loading Per Internal 20 Kg
Maximum Number of Internals 9
Net Weight Approx. 165 Kg
Pollution Degree 2
Programming Atmocontrol Software on a USB Stick for Programming, Managing and Transferring Programmes Via Ethernet Interface or USB Port
Set Up The Distance Between The Wall and The Rear of The Appliance Must Be at Least 15 Cm. The Clearance From The Ceiling Must Not Be Less Than 20 Cm and The Side Clearance From Walls or Nearby Appliances Must Not Be Less Than 5 Cm.
Setting Accuracy Temperature 0.1 °C
Temperature Sensor 2 Pt100 Sensors Din Class a In 4-Wire-Circuit for Mutual Monitoring, Taking Over Functions In Case of An Error
Timer Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute to 99 Days
Volume 256 L
Works Calibration Certificate Standard Values +10 °C and +37 °C, 60 % Rh at +30 °C
Controlcockpit Twindisplay. Adaptive Multifunctional Digital PID-Microprocessor Controller With 2 High-Definition TFT-Colour Displays.
Humidity Humidity Supply With Distilled Water From External Tank By Self-Priming Pump~Active Humidifying and De-Humidifying Adjustable From 10-80 % Rh With Digital Display of Relative Humidity - Resolution of Display 0.1 %, Setting Accuracy 0.5 %
Language Setting German, English, Spanish, French, Polish, Czech, Hungarian
Maximum Loading of Chamber 200 Kg
Overvoltage Category II
Setting Temperature Range 0 to +60 °C
Standard Accessories Water Tank Including Connection Hose
Voltage Electrical Load 230 V, 50 Hz ,1450 W
Working Temperature Range Without Humidity: 0 to +60 °C~from +10°C Up to +60°C With Humidity And/Or Light
Adjustable Parameters Temperature (Celsius or Fahrenheit), Fan Speed, Light, Programme Time, Time Zones, Summertime/Wintertime
Air Jacket Air Jacket Heating System for Gentle All-Around Heating
Defrosting Highly Efficient Automatic Defrosting System
Heating Concept No Drying-Up of The Load Caused By The Cooling Device Due to Separation of Thermal Jacket From Interior
Light Daylight and Uv-Light
No Records Found